Wyatt Technology
  • Home
  • DYNAMICS Features

DYNAMICS Features

Variable Data Filter

Outliers due to dust may be filtered out by a number of criteria. Apply your filter to all data, selected data, or even manually mark out individual acquisitions. Filtration criteria may be changed at any time.

Data Filter 1

Data Filter 2

Data Export and Reporting

Any display can be exported as a graph or as original data with a simple click of the mouse or by pressing shortcut keys. Results reports are partially customizable.

Data Export

Data Analysis

First, the basics: Size and size distributions by Cumulants and Regularization for DLS data, cumulative size distribution, as well as molar mass determination for SLS data from the DynaPro NanoStar. Statistical analysis on your measurements with display of mean, minimum, maximum, and standard deviation is provided. But there is more to your results than calculation of size: DYNAMICS can perform virtually any transition analysis, be it temperature or concentration dependence or any parameter measured or defined by the user. Linear, exponential and sigmoid curve analyses are provided for maximum flexibility.

Size and Size Distributions

Analyze protein and particle sizes using the method of Cumulants or Regularization. Report average radius, diameter and diffusion coefficient as well as the width of the distribution in terms of polydispersity, % polydispersity or polydispersity index (PDI).

In Regularization, size distributions may be viewed as Intensity or Mass distributions and custom data labels may created for each peak.

Distribution 1

Distribution 2

Cumulative Size Distributions

For a broad size distribution, it is important to control the entire distribution rather than the mean radius alone. DYNAMICS provides calculation of the percentage of samples below a certain size of particles (either diameter or radius), with values for D10, D50 and D90 (the size of the sample below 10%, 50% and 90% of the entire distribution lies, respectively). The width of the distribution, defined as (D90-D10)/D50, is calculated as well.

Cumulative Size Distribution

Transition Analysis

Monitor protein melting or unfolding. Determine temperature transitions for your biomolecule. Every molecule behaves differently. That's why DYNAMICS provides analysis in terms of the onset transition temperature for aggregating samples, midpoint for samples with a defined end state, and linear analysis for any type of transition.

Similarly, determine the Critical Micelle Concentration (CMC) with our Concentration Dependence analysis. There are no limitations when it comes to analyzing trends for your samples. Any transition can be analyzed with the Custom Parametric Analysis. Select parameters such as pH versus radius or salt concentration versus molar mass.

Even perform statistical analysis for duplicate or triplicate samples, or overlay the analysis curves for multiple samples for all of the analysis types listed above.

Absolute Molar Mass Determination

Measure the absolute molar mass of proteins and small polymers in batch with the dedicated static light scattering detector of the DynaPro NanoStar – simultaneously – while collecting DLS data. Compare the results for molar mass with the hydrodynamic radius to determine molecular conformation and distinguish between aggregation and protein unfolding.

For measurements of the absolute molar mass in chromatography mode or batch measurements of large polymers, we recommend the use of our multi-angle light scattering instruments.

Helpful Tools

Calculators are included in DYNAMICS to aid experiment design and evaluation of results. Use the Temperature Ramp Rate Calculator to design your thermal experiments for the DynaPro Plate Reader and NanoStar. The Optimization Calculator helps select the correct acquisition parameters and estimates the radius of your sample from a known molar mass. The Apparent Fraction Calculator determines the relative fraction of two species in equilibrium, such as a monomer-dimer. Additionally, the shape of proteins can be estimated from the Perrin Factor using the Axial Ratio Calculator.

New in DYNAMICS 7

Virtually analyze any transition in your samples, be it temperature, concentration or a custom parameter. Linear, exponential and sigmoid curve analyses are provided for maximum flexibility.

See what you can do with DYNAMICS

Watch our webinars or take a look at our Library that includes more than 10,000 peer-reviewed publications, featured articles and comprehensive application notes.

 

   

For essential macromolecular and nanoparticle characterization—The Solution is Light™

13 Key Questions to Ask

ultimate-guide

Get the inside scoop on buying a Multi-Angle Light Scattering (MALS) or Dynamic Light Scattering (DLS) instrument!

Request the Ultimate Guide today.
Get Ultimate Guide

 

Need more information?

Request Product Info
   

 

Wyatt Technology is the recognized leader in light scattering instrumentation and software for determining the absolute molar mass, size, charge and interactions of macromolecules and nanoparticles in solution.

Wyatt's line of multi-angle static light scattering products couple to size exclusion chromatography (SEC-MALS), field-flow fractionation (FFF-MALS), and stop-flow composition-gradient systems (CG-MALS). Our dynamic light scattering (DLS) products operate in traditional cuvette as well as on-line and automated, high-throughput modes. We also offer unique instruments for electrophoretic light scattering (MP-PALS), differential refractometry, and differential viscosity.



© Wyatt Technology Corporation. All rights reserved.