Optilab T-rEX

Optilab T-rEX, refractometer

 

Universal Detection for Chromatography and FFF Separations

Independent of chromaphores or fluorophores, differential Refractive Index (dRI) detectors serve as accurate and versatile concentration detectors in all types of solvents. dRI is part of standard instrumentation for a variety of macromolecular characterization techniques including standard chromatography, SEC-MALS, FFF-MALS and CG-MALS.

The Optilab® T-rEX (refractometer with EXtended range) is a unique dRI detector for standard HPLC/GPC with 256 times the detection power and 50 times the dynamic range of every other RI detector for chromatography in existence today, making it a valuable addition to any MALS setup.

  • Using a combination of cutting-edge semiconductor photodiode technology and proprietary computer algorithms, the Optilab T-rEX achieves an unprecedented combination of sensitivity and range. These features mean that it addresses both standard chromatographic applications and some challenges unique to light scattering measurements such as high concentrations, determination of sample refractive increments (dn/dc) and solvent refractive index.

    Key Benefits

    • Extraordinary dRI measurement range, -0.0047 - +0.0047 RIU (comparable to 25 mg/mL protein in PBS)
    • Highly sensitive, ±7.5 x 10-10 RIU across the entire measurement range
    • Measures solvent absolute refractive index, required for MALS calculations
    • Measures at the same wavelength as the MALS detector, for maximum accuracy in MALS calculations
    • Band broadening < 20 µL preserves SEC resolution
    • Temperature range 4°C - 65°C for proteins and polymers that require a range of temperatures
    • High-resolution, touch-screen front panel displays data graphs and diagnostics, even with the host computer turned off

    Unparalleled Features

    Even though the Optilab T-rEX offers a dRI measurement range orders of magnitude beyond that of other dRI detectors, unlike other detectors there are no range or gain settings in the T-rEX. The full range of instrument detection is always present, and the full sensitivity exists over the entire range.

    The T-rEX can also do something no other on-line refractive index detector can: it can measure the absolute refractive index of a solution. In addition, it can measure the dn/dc of a solvent at the same wavelength of light as the light scattering instrument. And just to make sure it can't be matched, you can replace the light source in the T-rEX for other wavelengths (e.g., 690, 633, 488, etc.) in just minutes!

    The T-rEX can go below ambient temperatures as easily as above ambient. No hassle temperature control can be programmed from 4°C to 65°C. Compatible with all HPLC systems.

  • Revolutionary dRI detection optics

    The Optilab T-rEX inherited the breakthrough optical design of the award-winning Optilab rEX dRI detector which makes use of a 512-element diode array and proprietary algorithms, instead of the usual bi-cell design, bringing dRI detection into the 21st century. The T-rEX added improvements in optical stability, temperature control, LED light source intensity and increased on-board computing power in order to enhance sensitivity and extend the temperature range over the rEX.

    Minimal loss of resolution

    Each detector downstream of SEC or FFF adds band broadening and dispersion, according to its internal fluidic volume. With a total flow cell volume of only 7.4 µL – 25% less than the leading HPLC refractometers – the Optilab does not impact SEC resolution adversely. This translates into minimized band broadening and better temperature stability.

  • SEC-MALS and FFF-MALS

    An Optilab T-rEX is generally combined with a DAWN HELEOS II or miniDAWN TREOS II MALS detector for anaysis of molar mass / molecular weight, conformation and conjugation of macromolecules in solution by means of SEC-MALS or FFF-MALS. It also combines with a ViscoStar II differential viscometer for analysis of intrinsic viscosity.

    General use

    Though its optimal use is in conjunction with MALS analysis, the Optilab T-rEX can be operated downstream of any standard GPC or HPLC system. While ASTRA utilizes its 22+-bit digital signal, it also offers a 18-bit analog output for use with 3rd-party systems, typically when MALS is not utilized.

  • The Optilab T-rEX offers an unparalleled dynamic range for use as both an online and batch measurement system. For batch measurement, sample is injected into the instrument (usually by means of a WISH Injection Module or Calypso II) in order to measure dn/dc or as part of a CG-MALS interaction analysis.

    High Concentration Option

    When the primary analysis desired is batch mode, the High Concentration version of the T-rEX is optimal since it extends the range of measurement by sevenfold compared to a standard T-rEX, while losing only a factor of 2 in sensitivity. The High Concentration T-rEX offers measurements up to 180 mg/mL of protein but may still be used in chromatography mode for 99% of all SEC-MALS and FFF-MALS measurements.

  • RI Calibration Kit - Pre-made RI calibration standards are available to speed up RI calibration. Can be used to calibrate any Optilab or third-party differential RI instrument.

    WISH Injection Module - The Wyatt Injection System High-Pressure (WISH) is ideal for use with an Optilab dRI detector for the determination of dn/dc in "batch" mode.

    Microbatch Kit - Used to inject samples into the flow cell of a MALS detector, and in determining dn/dc.

    SysTrack - Convenient shelving for holding multiple detectors in your experimental setup.

    Thermos - A temperature-controlled chamber for SEC/GPC columns and FFF channels.

  • Differential Refractive Index
    Standard T-rEX
       Range -0.0047 – +0.0047 RIU
       Peak-to-peak noise * ± 7.5 x 10-10 RIU
    High Concentration Option T-rEX
       Range -0.0026 – +0.034 RIU
       Peak-to-peak noise * ± 1.5 x 10-9 RIU
    Absolute Refractive Index
       Range 1.2 – 1.8 RIU
       Sensitivity 0.002 RIU
    Fluidics
       Band Broadening ** < 20 µL
       Flow cell 7.4 µL
       Inlet tubing (0.010" ID) 44 µL
       Outlet tubing (0.030" ID) 370 µL
       Back pressure created at inlet port <50 psi (3.5 bar) @ 0.5 mL/min of pure water, 20°C
       Maximum permissible back pressure at    outlet port 30 psi (2 bar)
       Wetted Materials 316 stainless steel, PTFE, fused silica
    Dynamic Range 22+ bits only via digital communication
    Data Acquisition Period 0.2 - 10 samples/second
    Light Source 660 nm standard; other wavelengths available
    Sample Temperature
       Control Range 4°C – 65°C, temperature regulated
       Temperature Regulation ± 0.005°C
    Safety Sensors Vapor and liquid (leak)
    Electronics
    On-board Computer
       Display / User Interface 6.4", high resolution, LCD color touch screen display
       Digital Communication Ethernet
    Auxiliary I/O
       Inputs Analog In (16 bits, ± 10 V A/D), Zero dRI, Purge, Recycle In, Autoinject in, Alarm In
       Ouputs Analog Out (18 bit dRI data), Autoinject Retransmit, Alarm Out, Recycle Out (to switch Orbit between waste and recycle)
    Dimensions 60 cm (L) x 36 cm (W) x 17 cm (H)

    * Short term peak-to-peak noise is measured as per ASTM-E1303-95(2000) using a 0.5 s collection interval (1-s time constant) and temperature set to 25°C.

    ** Peak broadening measured over full width at half max, flow rate = 0.3 mL/min.


    Host PC requirements may be found in Computer Requirements.

    Specifications subject to change without notice.

   

For essential macromolecular and nanoparticle characterization—The Solution is Light™

13 Key Questions to Ask

ultimate-guide

Get the inside scoop on buying a Multi-Angle Light Scattering (MALS) or Dynamic Light Scattering (DLS) instrument!

Request the Ultimate Guide today.
Get Ultimate Guide

 

Need more information?

Request Product Info
   

 

Wyatt Technology is the recognized leader in light scattering instrumentation and software for determining the absolute molar mass, size, charge and interactions of macromolecules and nanoparticles in solution.

Wyatt's line of multi-angle static light scattering products couple to size exclusion chromatography (SEC-MALS), field-flow fractionation (FFF-MALS), and stop-flow composition-gradient systems (CG-MALS). Our dynamic light scattering (DLS) products operate in traditional cuvette as well as on-line and automated, high-throughput modes. We also offer unique instruments for electrophoretic light scattering (MP-PALS), differential refractometry, and differential viscosity.



© Wyatt Technology Corporation. All rights reserved.