miniDAWN

DAWN

The Best in Basic Multi-Angle Light Scattering for Absolute Macromolecular Analysis.

MOLAR MASS

The miniDAWN® determines absolute molar mass and size to characterize proteins, peptides, small polymers and nanoparticles in solution. Coupled to size exclusion chromatography (SEC or GPC), it eliminates the uncertainty and hassle of column calibration, for true confidence in macromolecular characterization.


SUPERB SENSTIVITY

The miniDAWN not only offers superb sensitivity—it further enhances productivity thanks to greatly enhanced field serviceability and easy data analysis with One-Click Mw™.


COMPATIBLE WITH ASTRA

The miniDAWN is accompanied by ASTRA, the most versatile software package available for analysis of online multi-angle and dynamic light scattering. ASTRA and the miniDAWN incorporate advanced ease-of-use features that help guarantee excellent measurements with a single click.

Molar mass, absolutely

Wyatt's miniDAWN is most often used in conjunction with size exclusion chromatography (SEC-MALS) or field-flow fractionation (FFF-MALS) to determine distributions of molecular weight, size and composition. No need to make assumptions about molecular conformation or ideal column interactions.

Characterize:
  • Proteins, small peptides and oligonucleotides
  • Synthetic and natural polymers
  • Nanoparticles, virus-like particles and vesicles

Measurement Range:

  • MW from 200 Da to 10 MDa
  • rg from 10 to 50 nm, up to 150 nm with shape-specific models
  • sensitivity down to 25 ng of 100 kDa polystyrene in THF, injected on a standard GPC column
protein molar mass characterization 
        with miniDAWN

The miniDAWN determines molecular weight independently of column calibration. Here MALS shows that the earliest-eluting molecule does not have the highest molar mass.

The miniDAWN's performance is exceeded only by the DAWN which covers a wider range of size and molecular weight, with even better sensitivity and additional optional modules.

Ultrasonic Cleaning Included

Each miniDAWN includes an embedded COMET ultrasonic transducer that cleans the flow cell automatically by agitating the fluid and loosening particles from the glass surfaces.


Modularity = Productivity

The miniDAWN incorporates a fully modular design. Each module can be tested independently by the software to verify that it is functioning correctly. This imparts nearly complete field serviceability, since malfunctioning modules can be replaced and validated on-site by service engineers with no further calibration or alignment.

The miniDAWN is also field-upgradeable: the embedded WyattQELS DLS Module for measuring hydrodynamic radii from 0.5 to 50 nm can be installed on-site as well as in new units shipped from the factory.

Not just SEC-MALS...

Wyatt's miniDAWN may be used in batch (off-line) mode or in conjunction with a Calypso CG-MALS system for characterization of average solution properties as well as macromolecular interaction properties including protein-protein binding affinity and complex stoichiometry.

Simplicity personified

With miniDAWN and ASTRA, SEC-MALS became a whole lot easier. Sample-specific methods are set up in three short steps with ASTRA's Method Wizard, and new capabilities for automatic data processing mean that it takes just one click from your sample to a full report of the molecular weight and size results.

The miniDAWN's System Ready monitor will even let you know when the system is fully equilibrated with low baseline noise, ready to run.

Astra

Dynamic Light Scattering

WyattQELS - A dynamic light scattering (DLS) detection module which integrates inside the miniDAWN chassis to provide simultaneous DLS measurements in the same scattering volume. The optical collection fiber is held in a dedicated 135° fiber mount.

DynaPro NanoStar - Primarily used for batch DLS, the NanoStar does double duty as an online DLS detector by installing its optical collection fiber into the miniDAWN.


Basic On-line Configuration

The miniDAWN may be positioned downstream of all types of standard GPC, HPLC or FPLC systems for analysis of molar mass and size distributions (see SEC-MALS page), and derivatives such as conformational analysis. For those systems equipped with a UV, RI, fluorescence or other type of concentration detector, the miniDAWN accepts 2 analog inputs so a 3rd-party concentration signal may be used in MALS calculations of molar mass. The miniDAWN instrument is generally set up downstream of a UV detector and upstream of a RI detector.

In most cases it is beneficial to connect an Optilab as well as a UV detector. This permits universal concentration detection regardless of fluorophores or chromaphores. The combination of UV and RI signals is utilized in ASTRA's Conjugation Analysis algorithm to characterize binary complexes such as glycoproteins, PEGylated proteins, membrane proteins enveloped in surfactant, or block co-polymers.

miniDAWN Optilab
Advanced On-line Configurations

Wyatt's miniDAWN may also be connected to an Eclipse Field-Flow Fractionation system for characterization of macromolecules and nanoparticles from 1 nm to > 100 nm via FFF-MALS.

Both SEC-MALS and FFF-MALS will benefit from an additional WyattQELS module for measuring nanoparticle size via dynamic light scattering. The WyattQELS utilizes the same laser and flow cell volume as MALS detection. Its collection fiber, placed at 135° to the laser beam, does not displace any of the three detectors in the miniDAWN.

For analysis of natural and synthetic polymers, a ViscoStar online viscometer may also be added as well. Differential viscometry is an orthogonal means of determining molar mass and conformation.

MALS detectors may be operated in batch (unfractionated) mode when the analysis is targeted at:

Macromolecular interactions
  • In order to characterize macromolecular or nanoparticle complexes which are disrupted by column shear or dilution
  • In order to measure binding affinity or reaction kinetics of macromolecules such as protein-ligand interactions
Average solution properties
  • If the sample is not amenable to separation by SEC or FFF, to measure weight-average molar mass, and size as z-average radius
  • In order to validate SEC-MALS measurements:
    • to determine if large aggregates or other species are filtered out on the column
    • to determine if reversible aggregates dissociate subsequent to dilution on the column or FFF separation channel

Calypso - Automated sample preparation and delivery system for carrying out and analyzing composition-gradient MALS in a miniDAWN. Analyses include biomolecular interactions analyses high-concentration protein-protein interactions, Zimm plots and dn/dc as well as time-resolved MALS. Utilizes the CALYPSO software for interaction analysis.

Microbatch Kit - Used to inject samples into the flow cell of a MALS detector, and in determining dn/dc with an RI detector.

ASTRA - Our comprehensive software solution for MALS and DLS analysis in chromatography, AF4 or batch mode. ASTRA is available in a 21 CFR(11) compliant version and offers additional options such as particle analysis and a research database.

ASTRA's HPLC Control service allows for full digital synchronization between your HPLC system.

ASTRA's Method Wizard lets you set up a default method optimized for your sample type in three easy steps:

  1. Select experiment type
  2. Input parameters
  3. Hit Run

Once the method is ready, you are just a click away from MALS analysis with One-Click Mw™. ASTRA will:

  1. Synchronize data collection with your HPLC
  2. Autoset parameters to determine MW and
  3. Rg
  4. Generate custom reports and graphs
  5. Prepare for the next run
HPLC Manager

CALYPSO - Software for automated composition-gradient MALS experiments: control of the Calypso, data acquisition and analysis for biomolecular interactions and reaction kinetics as well as weight-average molar mass, z-average molecular size, and virial coefficients.

Measurements  
   Molar Mass Range 200 Da to 10 MDa1
   Molecular Size Range (Rg) 10 nm to 50 nm 1, up to 150 nm with shape-specific models
   Molecular Size Range (Rh, with    WyattQELS DLS module or
   DynaPro NanoStar)
In flow mode, 0.5 nm – 50 nm1,2; batch mode, 0.5 nm – 1 µm1
   Sensitivity

25 ng of 100 kDa polystyrene in THF3
500 ng of BSA in PBS4

Fluidics  
   Mobile Phase Compatibility All-solvent compatible (aqueous and organic). Wetted materials are 316 stainless steel, fused silica, and Kalrez.
Optics  
Detectors  
   MALS Detectors High-gain, high dynamic range, static light scattering detectors at 3 angles
   Auxiliary Detectors Laser monitor for stabilization feedback; forward transmission monitor to correct signals for absorbing samples and to assess data quality.
   A/D Resolution

Detector dynamic range > 16,000,000:1

DLS Detector (optional) WyattQELS dynamic light scattering module installs directly inside the miniDAWN chassis.

Alternatively, the optical fiber pickup of the DynaPro NanoStar cuvette-based DLS instrument may be installed in the miniDAWN.
Laser Properties  
   Laser Wavelength 658 nm (nominal). Each instrument is individually characterized.
   Laser Power Control Programmable 10% - 100%
Flow Cells Fused Silica, optimal for solvent refractive index < 1.50
Electronics  
   Analog Inputs

2 differential analog inputs with 24 bit resolution; Input range -10 V to +10 V

   Analog Outputs

1 analog output from user selectable measurements channels -10 V to +10 V

   Other Inputs/Outputs Alarm In, Alarm retransmit, Auto-Inject in, Autoinject contact closure, Recycle In, Recycle valve power
   Computer Interface Ethernet
   Processed Data Transmission Rate 36.6 Hz to 0.2 Hz
   Front Panel Display 162.5 mm, 16-bit, high resolution touch screen
Dimensions 60 cm (L) x 36 cm (W) x 17 cm (H)
1Typical. Actual range depends on dn/dc, sample concentration, sample conformation and chromatography conditions.

2Upper limit assumes a flow rate of 0.5 mL/min.

3Under HPLC-SEC conditions with 7.8x300 mm GPC columns.

4Under HPLC-SEC conditions with Wyatt 7.8x300 mm SEC protein columns.


Host PC requirements may be found in Computer Requirements.

Specifications subject to change without notice.

"An essential part of my routine activities! Fabulous!"
"The MALS detector is one of the champions in determining MW of large molecules, what’s fascinating about it is the fact that it could easily differentiate between 10kDa, 25 kDa, 49 kDa, 90.5 kDa with ease with extremely narrow margin of error. The product was delivered to us seem less was with true professionals, the next day the engineer drop by in our lab and installation was done in a flash. Whenever we encountered slight problems, they would always hear us patiently and delivered solutions over telephone, if not done then they would personally visit and rectify. I would highly recommend this detector." Debasis Day, Pfizer

"Highly recommended"
"High quality instrumentation and excellent customer service. Comprehensive service contract helps keep the instrument in excellent running condition for 10+ years of high volume use. Great software - highly refined and user-friendly. Excellent compatibility with third-party equipment." Matthew Slattery, Lifecore Biomedical

"Great results. We could not continue without it."
"My lab has been using this equipment for the past three years. It is so reliable and easy to use that it is used by all the students. We use it to determine the oligomeric states of our proteins and complexes and have obtained spectacular results with it. It has also completely changed our way of looking at size exclusion chromatography. We use for every single project now. Our best purchase." Laurent Terradot, CNRS, IBCP, Lyon

Other MALS Instruments

 dawn, molar mass determination, molar mass measurement, molar mass analysis, molecular weight measurement, molar mass characterization

DAWN® - The most sensitive MALS detector available, anywhere. Incorporates detectors at 18 angles to determine molar masses from 200 Da to 1 GDa and radii from 10 – 500 nm.

  • Standard option: ambient temperature
  • Heated/cooled option: -15°C to +150°C
  • High-temperature option: ambient to +210°C

The DAWN offers special options to handle fluorescent samples: fluorescence-blocking filters and an infrared, 785 nm laser.

microDAWN™ - The first MALS detector for UHPLC, with interdetector dispersion as low as 1.5 µL. Incorporates detectors at 3 angles to determine molar masses from 200 Da to 20 MDa and radii from 10 – 50 nm. Ambient only.